ANEL-Elektronik AG - Comparison of the devices |
||||||||||||||
NET-PwrCtrl - | I Generation | II Generation | ||||||||||||
HOME | PRO | POWER | POWER 19" | IO - PRO | IO - POWER | IO - 19" | ADV - PRO | ADV- POWER | ADV - 19" | HUT2 - HV | HUT2 - HV-S | HUT2 - LV | HUT2 - LV-S | |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|
Sockets / relays (controllable) | 4 (3) | 8 (8) | 8 (8) | 8 (8) | 8 (8) | 8 (8) | 8 (8) | 8 (8) | 8 (8) | 8 (8) | 8 relay |
8 relay |
8 relay |
8 relay potential free |
Input / Output - I / O (Bit) | - | - | - | - | 8 | 8 | 8 | - | - | - | 8 | 8 | 8 | 8 |
Supply voltage (V) | 230VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC 50-60Hz |
100-240VAC 50-60Hz |
8-30VAC 10-40VDC |
8-30VAC 10-40VDC |
Power consumption | 1,9 W | 3,6 W | 3,6 W | 3,6 W | 3,6 W | 3,6 W | 3,6 W | 3,6 W | 3,6 W | 3,6 W | 3,0 W | 3,0 W | 1,6 W | 1,6 W |
Max. Load each outlet | 2300 VA |
2300 VA |
2300 VA |
2300 VA |
2300 VA |
2300 VA |
2300 VA |
2300 VA |
2300 VA |
2300 VA |
max. 16 A | max. 16 A | max. 16 A | max. 16 A |
Max. Load of all outlets |
2300 VA |
2300 VA |
4600 VA |
4600 VA |
2300 VA |
4600 VA |
4600 VA |
2300 VA |
4600 VA |
4600 VA |
||||
Mains terminals (10A): | 1 x | 1 x | 2 x | 2 x | 1 x | 2 x | 2 x | 1 x | 2 x | 2 x | via panel |
via panel 8 x 16A |
via panel 8 x 16A |
via panel 8 x 16A |
Sensor port (RJ45) | ![]() |
![]() |
![]() |
![]() |
||||||||||
HTML - Changeable | - | - | - | - | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Wake on LAN (WOL) | - | - | - | - | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
I/O input -> switch socket (relay) with edge control and toggle | - | - | - | - | ![]() |
![]() |
- | - | - | ![]() |
![]() |
![]() |
![]() |
|
IP assignment: DHCP, Manual | all ![]() |
|||||||||||||
User - System | all ![]() |
|||||||||||||
Automatic time adjustment | all ![]() |
|||||||||||||
Sun timer - according to the calculations sunrises and sunsets | - | - | - | - | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Free choice of the HTTP port (0-65535) | all ![]() |
|||||||||||||
E-mail at the event. | all ![]() |
|||||||||||||
UDP, Ajax interface for own control | all ![]() |
|||||||||||||
Keepalive Function | all ![]() |
|||||||||||||
Timers per socket | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 6 | 5 | 5 | 5 | 5 |
Automatic and time-delayed (0-18,2h) switch on the sockets after the start (power failure). | - | - | - | - | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Pulse switching: To control external devices, only one pulse with adjustable length can be generated when switching. | - | - | - | - | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Switching distance of the relays with simultaneous switching can be determined in the range 0-255 milliseconds. | - | - | - | - | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Automatic switching on of the sockets after the start (power failure). | ![]() |
![]() |
![]() |
![]() |
- | - | - | - | - | - | - | - | - | - |
Logbook of the last 40 events. | ![]() |
![]() |
![]() |
![]() |
- | - | - | - | - | - | - | - | - | - |
Logbook of the last 128 events. Power failures are registered. (Logbook is kept without power). | - | - | - | - | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Save configuration | all ![]() |
|||||||||||||
Firmware upgrade via Ethernet | all ![]() |
|||||||||||||
Sturdy aluminum housing, child safety in the sockets | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
- | - | - | - |
Online-Shop | HOME | PRO | POWER | POWER 19" | IO - PRO | IO - POWER | IO - 19" | ADV - PRO | ADV- POWER | ADV - 19" | HUT2 - HV | HUT2 - HV-S | HUT2 - LV | HUT2 - LV-S |
© 2019 ANEL-Elektronik AG - Comparison of the devices |